News/Washington chemical tank was called unfit for service before…
NSR-2026-0828-106894News Report·EN·Public Health

Washington chemical tank was called unfit for service before deadly failure, investigators find

A federal report indicates that a chemical tank at Nippon Dynawave Packaging Company in Longview, Washington, was deemed "not fit for continued service" by an inspection contractor 10 months before its catastrophic failure on May 26, 2026. This failure resulted in the deaths of 11 workers and injured several others.

Associated Press (AP)Filed 2026-08-28 · 12:23 GMTLean · CenterRead · 4 min
Washington chemical tank was called unfit for service before deadly failure, investigators find
Associated Press (AP)FIG 01
Reading time
4min
Word count
927words
Sources cited
2cited
Entities identified
10entities
Quality score
100%
§ 01

Briefing Summary

AI-generated
NEWSAR · AI

A federal report indicates that a chemical tank at Nippon Dynawave Packaging Company in Longview, Washington, was deemed "not fit for continued service" by an inspection contractor 10 months before its catastrophic failure on May 26, 2026. This failure resulted in the deaths of 11 workers and injured several others. Despite multiple inspections between July 2025 and February 2026 revealing significant thinning of the tank's walls below safe thickness, the company reportedly took no corrective actions, such as internal inspections or shell repairs, and did not remove the tank from service. The U.S. Chemical Safety Board is continuing its investigation into the cause of the incident, which involved the release of approximately 900,000 gallons of caustic white liquor. The company has not yet commented on the findings.

Confidence 0.90Sources 2Claims 5Entities 10
§ 02

Article analysis

Model · rule-based
Framing
Public Health
Human Interest
Tone
Measured
AI-assessed
CalmNeutralAlarmist
Factuality
0.90 / 1.00
Factual
LowHigh
Sources cited
2
Limited
FewMany
§ 03

Key claims

5 extracted
01

The tank failure released roughly 900,000 gallons of white liquor, a caustic liquid used in papermaking.

factual
Confidence
1.00
02

Multiple inspections found 'significant thinning' below the minimum safe thickness in the tank.

factualU.S. Chemical Safety Board
Confidence
1.00
03

Nippon Dynawave Packaging Company did not perform internal inspections or shell repairs between July 2025 and the May 2026 failure.

factualU.S. Chemical Safety Board
Confidence
1.00
04

The tank failure killed 11 people and injured several others and one firefighter.

factual
Confidence
1.00
05

An inspection contractor found a chemical tank at a Washington state paper mill “not fit for continued service” 10 months before it failed.

factualU.S. Chemical Safety Board
Confidence
1.00
§ 04

Full report

4 min read · 927 words
Washington chemical tank was called unfit for service before deadly failure, investigators find 1 of 2 | Damage is seen at Nippon Dynawave Packaging Co., after a tank containing hazardous liquid imploded, on Tuesday, May 26, 2026, in Longview, Wash. (Karen Ducey/The Seattle Times via AP, File) 2 of 2 | Yellow police tape is seen on May 27, 2026 outside the Longview, Wash. paper mill where a deadly chemical tank failure occurred. (AP Photo/Claire Rush, File) By Claire Rush Updated 3:11 PM MESZ, August 28, 2026 Add AP News on Google Add AP News as your preferred source to see more of our stories on Google. Share Share Facebook Copy Link copied Print Email X LinkedIn Bluesky Flipboard Pinterest Reddit An inspection contractor found a chemical tank at a Washington state paper mill “not fit for continued service” 10 months before it failed in May, killing 11 in one of the deadliest U.S. workplace disasters in recent decades, according to a federal report released Friday. The U.S. Chemical Safety Board’s update about the May 26 failure in Longview, which expelled enough caustic liquid to blow out building walls, is part of an ongoing investigation. The federal agency said it is still determining the cause of the failure. The board found that the contractor provided Nippon Dynawave Packaging Company with recommendations for internal inspections and shell repairs, but the company did none between a July 2025 inspection and the May 2026 failure. An email seeking comment was sent to Nippon Dynawave. A person who answered the phone at Nippon’s plant in Longview declined to comment, and a message was left seeking comment. Multiple inspections found safety problems before tank failure In July 2025, the contractor found “significant thinning” below the minimum safe thickness in the lower regions of the tank after an external inspection, according to the board’s report. The minimum safe thickness is a threshold that measures a tank’s ability to contain the pressure of the liquid and support the tank’s weight, the report said. Victims of quintuple homicide in Oregon include suspect’s girlfriend and her relatives 1 MIN READ FAA orders crack inspections for hundreds of Boeing 737 Max jets 2 MIN READ Firefighters get a handle on Spokane wildfires as tens of thousands remain evacuated 2 MIN READ The same contractor inspected the exterior of the tank in October 2025 and February 2026 and both times identified that “large portions of the tank remained thinner than the calculated minimum safe wall thickness.” “The company also did not remove the tank from operation or derate the tank for reduced service,” the board said. The tank failure released roughly 900,000 gallons (3.4 million liters) of a liquid known as white liquor that is used to break down wood for making paper products and is capable of causing severe burns. In addition to the workers killed, several others and one firefighter were injured. The board’s Chairperson Steve Owens said in a statement “we are greatly concerned that the tank was not promptly removed from service or properly repaired after the clear findings in the inspection report.” In an excerpt of the July 2025 inspection included in the board’s update, the recommendations were noted as “Priority 1: Not fit for continued service unless corrected,” with a “high likelihood/consequence of failure (or) critical code/standard deficiency.” “Owner should plan to have an internal inspection performed in order to determine the extent of the required repairs. It’s likely that the entire shell course should be replaced,” the inspection excerpt says. The inspection was completed by Applied Technical Services LLC. The federal report did not specify why the company was conducting the inspections. A message was left seeking comment from Applied Technical Services. Tank failure occurred as employees started to arrive to work The catastrophic failure hit just minutes after employees began arriving around 7 a.m., the board’s report said. Shortly before 2 a.m., a vessel at the facility called a digestor was removed from service for repairs. As a result, the tank stopped sending white liquor into the digestor. But more white liquor continued to flow into the tank, causing it to approach full capacity around 6:20 a.m. It failed less than an hour later, the report said. After flooding the courtyard, crushing vehicles and destroying part of one of the surrounding buildings, the liquid flowed into the buildings’ lower floors, where workers were holding morning meetings. All eight workers in the electrical maintenance shop as well as a worker in the courtyard were killed. In the mechanical maintenance shop, five employees and the foreman escaped, but two were killed from exposure to the chemical, the report said. Two of the people who escaped were seriously injured due to chemical burns. The company radioed for its medical emergency response team but didn’t explain that white liquor had been released, according to the report. A member of the team waded into a pool of white liquor to try to rescue an employee, thinking it was water, and was seriously injured from chemical burns. Earlier this week, the Washington Department of Ecology issued notice of 35 environmental violations to Nippon Dynawave. The state agency oversees the facility’s air and water quality permits and compliance with environmental waste laws. The board said its investigation is ongoing and that its complete findings will be included in its final investigation report. Associated Press writers Hallie Golden and Dave Collins contributed to this report. Claire Rush Rush is an Associated Press reporter covering Oregon state government and general news in the Pacific Northwest more broadly. twitter mailto
§ 05

Entities

10 identified
§ 06

Keywords & salience

8 terms
chemical tank failure
1.00
workplace disaster
0.90
safety inspection
0.80
unfit for service
0.70
hazardous liquid
0.60
federal report
0.50
nippon dynawave packaging company
0.50
tank thickness
0.40
§ 07

Topic connections

Interactive graph
Network visualization showing 2 related topics
View Full Graph
Person Organization Location Event|Click node to navigate|Edge numbers = shared articles